  ARM Give a man a fire and he's warm for a day, but set fire to him and he's warm for the rest of his life (Terry Pratchett, Jingo)

Intel takes deep dive into immersion cooling with GRC

(2022/07/15)


Intel has partnered with Green Revolution Cooling (GRC) on a joint whitepaper about liquid immersion cooling. The pair make the case for sustainability, claiming it reduces the power needed to cool a datacenter as well as cutting operational costs.

The companies announced a multi-year project in January aimed at helping the datacenter industry reduce the environmental impact of digital infrastructure. GRC also received a $28 million investment from South Korean company SK Lubricants in March.

GRC, co-author of the [1]whitepaper , specializes in immersion cooling technology, and Intel also unveiled in May that it is [2]building its own lab to qualify, test, and demo immersion-cooling technologies.

[3]

Central to the argument is that datacenters use approximately 1.5-2 percent of the world's entire electricity supply. Left unchecked, this could expand to as much as 13 percent in the next decade. This references [4]work by David Mytton , a former researcher on the sustainability team at Uptime Institute.

[5]

[6]

Up to 40 percent of this power consumption is estimated to go into cooling all datacenter infrastructure and, as the power density of processors continues to increase, servers are now pushing the limits of what air cooling systems can cope with. This chimes with what Cisco told our sister site [7]The Next Platform recently, warning that some of the upcoming generation of CPUs from Intel and AMD are set to reach the threshold where air cooling is no longer sufficient.

Many datacenter operators are aware of this with as many as three-quarters of are now thinking about the importance of sustainability as a competitive differentiator, according to Intel and GRC findings. However, the pair claim that datacenters have hit a wall in power usage effectiveness (PUE), which on average has been hovering around 1.6 for almost a decade.

[8]Intel's net positive water use only tells part of the story

[9]Your top 5 liquid cooling quandaries answered, according to Omdia

[10]Fujitsu: Ammonia could power datacenters in the near future

[11]Microsoft's Dublin datacenter to help take pressure off Ireland's renewable energy

Addressing that 40 percent of power consumed by cooling systems is a start, and the whitepaper adds that the removal of internal server fans reduces energy consumption by 10-15 percent. The hot components inside the chassis still have to be cooled somehow, but that could just as easily be a system where a liquid coolant is circulated through heatsinks attached to components such as CPUs.

Inspur, supplier of servers to the hyperscale market, is now offering such a system as an option [12]across its entire portfolio .

[13]

However, Intel and GRC contend that full immersion liquid cooling enables more servers to be fitted into a given space. They are perhaps on shakier ground with the assertion that this reduces the amount of equipment such as switch gear, cabling, and stand-by generators due to the decreased power load, which they say means lower capex and opex costs.

But Omdia's Senior Principal Analyst for Data Center Physical Infrastructure, Moises Levy, told The Register this week that there are [14]pitfalls to watch out for with liquid cooling , including the operational costs and procedures required for using this technology.

"People sometimes don't know they need a filtering system, they need software, they will be tracking the quality of dielectric fluids," he said. "It's another type of monitoring which requires higher skilled labor."

[15]

Intel said that as industries such as the cloud and telecom markets move to adopt liquid cooling solutions, the company is designing silicon with immersion cooling in mind, which means rethinking elements like the heat sink. ®

Get our [16]Tech Resources



[1] https://www.grcooling.com/learning-center/the-sustainable-data-center-transformation

[2] https://www.theregister.com/2022/05/19/intel_immersion_lab/

[3] https://pubads.g.doubleclick.net/gampad/jump?co=1&iu=/6978/reg_onprem/front&sz=300x50%7C300x100%7C300x250%7C300x251%7C300x252%7C300x600%7C300x601&tile=2&c=2YtGPHuWFQqFFQ2qX1KAP5QAAAAw&t=ct%3Dns%26unitnum%3D2%26raptor%3Dcondor%26pos%3Dtop%26test%3D0

[4] https://davidmytton.blog/how-much-energy-do-data-centers-use/

[5] https://pubads.g.doubleclick.net/gampad/jump?co=1&iu=/6978/reg_onprem/front&sz=300x50%7C300x100%7C300x250%7C300x251%7C300x252%7C300x600%7C300x601&tile=4&c=44YtGPHuWFQqFFQ2qX1KAP5QAAAAw&t=ct%3Dns%26unitnum%3D4%26raptor%3Dfalcon%26pos%3Dmid%26test%3D0

[6] https://pubads.g.doubleclick.net/gampad/jump?co=1&iu=/6978/reg_onprem/front&sz=300x50%7C300x100%7C300x250%7C300x251%7C300x252%7C300x600%7C300x601&tile=3&c=33YtGPHuWFQqFFQ2qX1KAP5QAAAAw&t=ct%3Dns%26unitnum%3D3%26raptor%3Deagle%26pos%3Dmid%26test%3D0

[7] https://www.nextplatform.com/2022/04/27/cisco-surfs-the-liquid-cooling-wave-in-the-datacenter/

[8] https://www.theregister.com/2022/07/13/intels_net_positive_water_use/

[9] https://www.theregister.com/2022/07/13/liquid_cooling_questions/

[10] https://www.theregister.com/2022/07/12/fujitsu_ammonia_datacenters/

[11] https://www.theregister.com/2022/07/08/microsoft_grid_interactive_ups_dublin/

[12] https://www.theregister.com/2022/07/07/inspur_liquid_cooling/

[13] https://pubads.g.doubleclick.net/gampad/jump?co=1&iu=/6978/reg_onprem/front&sz=300x50%7C300x100%7C300x250%7C300x251%7C300x252%7C300x600%7C300x601&tile=4&c=44YtGPHuWFQqFFQ2qX1KAP5QAAAAw&t=ct%3Dns%26unitnum%3D4%26raptor%3Dfalcon%26pos%3Dmid%26test%3D0

[14] https://www.theregister.com/2022/07/13/liquid_cooling_questions/

[15] https://pubads.g.doubleclick.net/gampad/jump?co=1&iu=/6978/reg_onprem/front&sz=300x50%7C300x100%7C300x250%7C300x251%7C300x252%7C300x600%7C300x601&tile=3&c=33YtGPHuWFQqFFQ2qX1KAP5QAAAAw&t=ct%3Dns%26unitnum%3D3%26raptor%3Deagle%26pos%3Dmid%26test%3D0

[16] https://whitepapers.theregister.com/



Fluid choice

Anonymous Coward

The major issue is the choice of cooling fluid as it is in close contact with all the components in the system and it will interact with some of them. All components include what you make the boards from the sealant and internals of discrete components on the board as well as all of the chips. Expect some short life times for the first set of systems

Re: Fluid choice

Anonymous Coward

I've never had a problem when using level 4 and 5 mil-spec board. Even when sea water was used as the coolant - yes you did read that correctly! And no, I most definately cannot give any more details!

Someday, Weederman, we'll look back on all this and laugh... It will
probably be one of those deep, eerie ones that slowly builds to a
blood-curdling maniacal scream... but still it will be a laugh.
-- Mister Boffo